ONE (1) RECONDITIONED 2000 AMP MITSUBISHI SF-6 CIRCUIT BREAKER 200-SFMT-40/50B 242kV Max, 60hz. 900kV BIL, 1.0, Voltage, Factor 3 Cycle Interrupt 40kA Short • Warranty - 12 months ( from 1st Energization) • Sale Condition: Equipment is sold fully reconditioned, tested and guaranteed • Standard Lead Time: Ready to ship in 22-24 weeks from ROO • Shipping Terms: Customer Arrangements
ONE (1) UNUSED 1200 AMP, ABB, AMVAC, 4160 V, 2009, ELECTRICALLY OPERATED VACUUM CIRCUIT BREAKER TYPE MA3C1100000001P ABB CH00145A01CB03 ANSI C37.04 REV 2001 CAPACITOR SWITCHING - 400 AMP GEN. PURPOSE RATING 25 AMPS CABLE CHARGING 4.76 KV MAXIMUM VOLTAGE 1200 AMP CONTINUOUS CURRENT 40 KA SHORT CIRCUIT @ 5 KV 1.0 K FACTOR 60 KV BIL 50/60 HERTZ
ONE (1) 4000 AMP SIEMENS SF6 CIRCUIT BREAKER, TYPE SPS2-72.5-40-2, 72.5 KV MAX. VOLTS, 1.0 K RANGE FACTOR, 3.0 CYCLE INTERRUPT, 40 KA SHORT CIRCUIT, 10 KA OUT OF PHASE, 60 HERTZ.
Reconditioned ABB-HITACHI 242KV SF6 Circuit Breaker Type: 242 PA 40-20 Max Voltage: 242 KV Short Circuit: 40 KA Freq: 60Hz Impulse Withstand: 900KV Interrupting Time: 2 Cycles Continuous Current: 2000A Voltage Factor "K": 1.0 Transient Overvoltage: 2.0 Line Charging Currnet: 200A Isolated Shunt Cap Bank Current: 400A Back To Back Shunt Cap Bank: 400A Transient Inrush Peak: 20KA Transient Inrush Freq: 4250Hz Out of Phase Switching: 10KA *Additional Information on Provided Nameplate*
SF6 Gas breaker Fully Reconditioned to OEM Standards Siemens 145kv SF6 Gas breakers to OEM standards see below Type: SPS-145-40-2000 2000Amp 145kV 40kA 60Hz. (1) Year Warranty
RECONDIITIONED 2000 AMP ABB SF6 CIRCUIT BREAKER TYPE 121PM31-20 121 KV MAX. VOLTAGE 31.5 KA SHORT CIRCUIT 3 PHASE 60 HERTZ 550 KV BIL 3 CYCLE INTERRUPT 1.0 RANGE FACTOR K 6,106 LBS. W/O GAS 6,170 LBS. WITH GAS 64 LBS. OF GAS MFG. 1997 INST. MANUAL 33-210C FSA-2 OPERATING MECHANISM 125 VDC CLOSE & TRIP 125 VDC MOTOR 3 X 2000:5A MRCT'S (C-800 ON 1200:5 TAP) 3 X 3000:5A MRCT'S (C-800 ON 2000:5 TAP)
ONE (1) UNUSED 72.5KV 2000AMP 6SF 40KA 60HZ. GE CIRCUIT BREAKER
3000 AMP ABB SF6 LIVE TANK CIRCUIT BREAKER TYPE HPL362/31B2 362000 V 1300KV BIL 3 POLE 50 KA SHORT CIRCUIT 20 CYCLE INTERRUPTING TIME OPERATING DEVICE 205A101-01 BLG1002 MAX. GAS PRESSURE 116 PSI ABS FILLING PRESSURE AT 20 DEG. C 73 PSI ABS SIGNAL/BLOCKING AT 20 DEG. C 65/62 PSI ABS 125 VDC CLOSE AND TRIP 120 VAC/125 VDC MOTOR VOLTAGE 22 AMP CLOSING/TRIPPING CURRENT 66 LBS. OF GAS 15,995 LBS. INCLUDING GAS SCH. DWG. 995D701 EACH POLE HAS AN OPERATING MECHANISM TIED TO A COMMON CONTROL BOX. EACH POLE IS 20'H X 14'7-3/4"L X 4'1"W OVER CAPACITOR EXTERNAL CT'S ARE NOT INCLUDED (1) YEAR WARRANTY INCLUDED
TYPE SPS2-72.5-31.5-2 72.5 kV 1.0 kA RATED FACTOR 3 CYCLE INTERRUPT 31.5 kA SHORT CIRCUIT 7.9 kA OUT OF PHASE CURRENT 60HZ 350 kV BIL 65 PSIG FILL PRESSURE 56 PSIG ALARM PRESSURE FA2.20 Mechansim 125VDC CLOSE AND TRIP 120VAC MOTOR 4800LBS WITH GAS 33LBS OF GAS 3x BYM CTs 1000:5 metering class 12x MRCTs 1200:5 C 400
OD3Mag™ Substation Circuit Breaker, Outdoor, rated for 15kV, 2000A, 25kA, consisting of (1) frame fully assembled and tested. Refer to item bill of material for details. Call or Email CTG.