ONE (1) 2000 AMP GE/HITACHI SF6 CIRCUIT BREAKER TYPE HVB 242 40000 242 KV MAXIMUM 10 K RATED VOLTAGE RANGE 950 KV BIL 3 PHASE 60 HERTZ 40 KA SHORT CIRCUIT 3 CYCLES INTERRUPTING 75 PSIG NORMAL 64 PSIG MINIMUM 220 LBS. GAS 21,000 LBS. MPR-3 PNEUMATIC OPERATING MECHANISM WIRING DIAGRAM H24201314 125 VDC CLOSE & TRIP AMBIENT DESIGN TEMP. - +40 TO -50 DEG. C HEATING RATING 838 KW, 208 VAC 6 CT'S EXTRA CT'S AVAILABLE AT ADDITIONAL COST USED / GOOD CONDITION
ONE (1) UNUSED 1200 AMP, ABB, AMVAC, 4160 V, 2009, ELECTRICALLY OPERATED VACUUM CIRCUIT BREAKER TYPE MA3C1100000001P ABB CH00145A01CB03 ANSI C37.04 REV 2001 CAPACITOR SWITCHING - 400 AMP GEN. PURPOSE RATING 25 AMPS CABLE CHARGING 4.76 KV MAXIMUM VOLTAGE 1200 AMP CONTINUOUS CURRENT 40 KA SHORT CIRCUIT @ 5 KV 1.0 K FACTOR 60 KV BIL 50/60 HERTZ
FOUR (4) X SF6 145kV HITACHI 3000AMP 40kA 50/60HZ. CIRCUIT BREAKERS REF. NO. CBK-06-5007 TECHNICAL SPECIFICATIONS: Type: HS145B Mfg. HVB AE Power Systems, Inc. Rated Max. Voltage: 145kV Rate Power Frequency: 50/60Hz. Rated Voltage Range Factor, K: 1.0 Rate Shot-Circuit Current: 40kA Percent DC Component: 55% Rated Interrupting Time: 3 Cycles Rated Continuous Current: 3000AMP Rated Full Wave Lighting Impulse Withstand Voltage <Bil>: • Terminal To Ground Circuit Breaker Closed: 650kV • Terminal To Ground Circuit Breaker Open: 650kV Total Weight of Breaker w/Gas - 7000Lbs. (3175) kg Total Weight of SF6 Gas - 44Lbs. (20) kg Short Time Duration: 3 Seconds Operating Mechanism: HVB S1 Reconditioned with (1) Year Warranty
ONE (1) 4000 AMP SIEMENS SF6 CIRCUIT BREAKER, TYPE SPS2-72.5-40-2, 72.5 KV MAX. VOLTS, 1.0 K RANGE FACTOR, 3.0 CYCLE INTERRUPT, 40 KA SHORT CIRCUIT, 10 KA OUT OF PHASE, 60 HERTZ.
Reconditioned ABB-HITACHI 242KV SF6 Circuit Breaker Type: 242 PA 40-20 Max Voltage: 242 KV Short Circuit: 40 KA Freq: 60Hz Impulse Withstand: 900KV Interrupting Time: 2 Cycles Continuous Current: 2000A Voltage Factor "K": 1.0 Transient Overvoltage: 2.0 Line Charging Currnet: 200A Isolated Shunt Cap Bank Current: 400A Back To Back Shunt Cap Bank: 400A Transient Inrush Peak: 20KA Transient Inrush Freq: 4250Hz Out of Phase Switching: 10KA *Additional Information on Provided Nameplate*
SF6 Gas breaker Fully Reconditioned to OEM Standards Siemens 145kv SF6 Gas breakers to OEM standards see below Type: SPS-145-40-2000 2000Amp 145kV 40kA 60Hz. (1) Year Warranty
RECONDIITIONED 2000 AMP ABB SF6 CIRCUIT BREAKER TYPE 121PM31-20 121 KV MAX. VOLTAGE 31.5 KA SHORT CIRCUIT 3 PHASE 60 HERTZ 550 KV BIL 3 CYCLE INTERRUPT 1.0 RANGE FACTOR K 6,106 LBS. W/O GAS 6,170 LBS. WITH GAS 64 LBS. OF GAS MFG. 1997 INST. MANUAL 33-210C FSA-2 OPERATING MECHANISM 125 VDC CLOSE & TRIP 125 VDC MOTOR 3 X 2000:5A MRCT'S (C-800 ON 1200:5 TAP) 3 X 3000:5A MRCT'S (C-800 ON 2000:5 TAP)
ONE (1) UNUSED 72.5KV 2000AMP 6SF 40KA 60HZ. GE CIRCUIT BREAKER
3000 AMP ABB SF6 LIVE TANK CIRCUIT BREAKER TYPE HPL362/31B2 362000 V 1300KV BIL 3 POLE 50 KA SHORT CIRCUIT 20 CYCLE INTERRUPTING TIME OPERATING DEVICE 205A101-01 BLG1002 MAX. GAS PRESSURE 116 PSI ABS FILLING PRESSURE AT 20 DEG. C 73 PSI ABS SIGNAL/BLOCKING AT 20 DEG. C 65/62 PSI ABS 125 VDC CLOSE AND TRIP 120 VAC/125 VDC MOTOR VOLTAGE 22 AMP CLOSING/TRIPPING CURRENT 66 LBS. OF GAS 15,995 LBS. INCLUDING GAS SCH. DWG. 995D701 EACH POLE HAS AN OPERATING MECHANISM TIED TO A COMMON CONTROL BOX. EACH POLE IS 20'H X 14'7-3/4"L X 4'1"W OVER CAPACITOR EXTERNAL CT'S ARE NOT INCLUDED (1) YEAR WARRANTY INCLUDED