3000 AMP ABB SF6 LIVE TANK CIRCUIT BREAKER TYPE HPL362/31B2 362000 V 1300KV BIL 3 POLE 50 KA SHORT CIRCUIT 20 CYCLE INTERRUPTING TIME OPERATING DEVICE 205A101-01 BLG1002 MAX. GAS PRESSURE 116 PSI ABS FILLING PRESSURE AT 20 DEG. C 73 PSI ABS SIGNAL/BLOCKING AT 20 DEG. C 65/62 PSI ABS 125 VDC CLOSE AND TRIP 120 VAC/125 VDC MOTOR VOLTAGE 22 AMP CLOSING/TRIPPING CURRENT 66 LBS. OF GAS 15,995 LBS. INCLUDING GAS SCH. DWG. 995D701 EACH POLE HAS AN OPERATING MECHANISM TIED TO A COMMON CONTROL BOX. EACH POLE IS 20'H X 14'7-3/4"L X 4'1"W OVER CAPACITOR EXTERNAL CT'S ARE NOT INCLUDED (1) YEAR WARRANTY INCLUDED
ONE (1) UNUSED 72.5KV 2000AMP 6SF 40KA 60HZ. GE CIRCUIT BREAKER
THREE PHASE, 60 HERTZ, CLASS OA/FA/FOA IMPEDANCE 7.01%, 65 C RISE, ALUMINUM WINDINGS TOP-TOP BUSHINGS, WINDING TEMPERATURE GAUGE, CT's 600:5 RATIO DRAIN & SAMPLE VALVE, LIQUID LEVEL GAUGE, LIQUID TEMPERATURE GAUGE HV: 138000 DELTA BIL: 650 kV LV: 13800 WYE BIL: 110 kV HV Taps: 144900-141450-138000-134450-13110
Automatic Transfer Switch, ZTG T-Series, 400 A-600 A, ZGOL3SX12-BX1XX2X ZTG OT 600A3PH Swt Neu N1 6,295.10 6,295.10 General Purpose Commercial and Industrial Automatic Transfer Switch 600 A, 3 Phase (4 Pole), Open Transition NEMA 1 Enclosure 2 NO (Normally Open) and 2 NC (Normally Closed) Auxiliary Contacts Switched Neutral No Meters GB1 - (3)#8-1/0 Ground Bar Additional 2 I/O, programmable T1-Panel Voltage agnostic, Rated for 200 to 480V line to line voltage Standard Application-Sources on Bottom
RECONDIITIONED 2000 AMP ABB SF6 CIRCUIT BREAKER TYPE 121PM31-20 121 KV MAX. VOLTAGE 31.5 KA SHORT CIRCUIT 3 PHASE 60 HERTZ 550 KV BIL 3 CYCLE INTERRUPT 1.0 RANGE FACTOR K 6,106 LBS. W/O GAS 6,170 LBS. WITH GAS 64 LBS. OF GAS MFG. 1997 INST. MANUAL 33-210C FSA-2 OPERATING MECHANISM 125 VDC CLOSE & TRIP 125 VDC MOTOR 3 X 2000:5A MRCT'S (C-800 ON 1200:5 TAP) 3 X 3000:5A MRCT'S (C-800 ON 2000:5 TAP)
ONE (1) 30/33.6/40/44.8/50/56 MVA WAUKESHA, GENERATOR STEP-UP TRANSFORMER, 3 PHASE, 60 HERTZ, CLASS ONAN/ONAF/ONAF, 55/65 DEG. C RISE, 9,69% IMPEDANCE, COPPER WINDINGS, 6 X HV 600:5, MRCT'S C800, 6 X LV 1200:5 MRCT'S C800, CONSERVATOR, MFG. 2003 HIGH VOLTAGE: 138000GRDY/79670 BIL: 650 KV LOW VOLTAGE: 34500GRDY/19920 BIL: 200 KV TERTIARY: 12470 VOLTS BIL: 110 KV TAPS: 144900-141450-138000-134550-131100
SF6 Gas breaker Fully Reconditioned to OEM Standards Siemens 145kv SF6 Gas breakers to OEM standards see below Type: SPS-145-40-2000 2000Amp 145kV 40kA 60Hz. (1) Year Warranty
New 60/80MVA 60Hz. 3 Phase Step Down Transformer HV: 69 kV LV : 34.5 kV Winding Type: Copper Function: Step-Down
JSHP TRANSFORMER CO. LTD. DE-ENERGIZED TAP CHANGER TYPE TRANSFORMER 112 MVA 138 kVD – 34.5 kVY 60HZ 3-PHASE OUTDOOR TRANSFORMER HV: 138000 VBOLTS XV: 34500GRDY/19918 VOLTS HV: 112.5/150/187.5 MVA CONT. TEMP. RISE 65°c XV: 112.5/150/187.5 MVA CONT. TEMP. RISE 65°c CODE NO. ANSI C57.12.00 2015 CLASS: ONAN/ONAF1/ONAF2
Reconditioned ABB-HITACHI 242KV SF6 Circuit Breaker Type: 242 PA 40-20 Max Voltage: 242 KV Short Circuit: 40 KA Freq: 60Hz Impulse Withstand: 900KV Interrupting Time: 2 Cycles Continuous Current: 2000A Voltage Factor "K": 1.0 Transient Overvoltage: 2.0 Line Charging Currnet: 200A Isolated Shunt Cap Bank Current: 400A Back To Back Shunt Cap Bank: 400A Transient Inrush Peak: 20KA Transient Inrush Freq: 4250Hz Out of Phase Switching: 10KA *Additional Information on Provided Nameplate*