CTG Power Systems Intnl., LLC is offering for one (1) GE MS-7000 Heavy-Duty Gas Turbine (7EA) 81 MW nominal with water injection and inlet flogging system consisting of the following basic scope of supply: SPECIFICATIONS: • One (1) GE Model MS-7000 Gas Turbine - Mfg. 1999 • Duel Fuel ( Natural Gas and Liquid No. 2 Diesel) • Base Rated 81,730 KW / Peak Rated 89,490 KW • Heat Rate at ISO:10,480 Btu/kWh • RPM: 3600 rpm / CCW rotation • Liquid Fuel Pump and Supply System • GE Air Cooled generator, 104000 KVA, 13.8 kV, 3 Phase 0.9 power factor, 2-pole, 4425 Amps, 300V Exciter Volts, Field Amps: 874, 3600 RPM • Enclosure: Outdoor Housing
CTG Power Systems Intnl., LLC is offering for one (1) GE MS-7000 Heavy-Duty Gas Turbine (7EA) 81 MW nominal with water injection and inlet flogging system consisting of the following basic scope of supply:
SPECIFICATIONS:
CTG~GT2F-0419_ONE (1) DECOMMISSIONED GE MODEL MS-7000 (7EA) 60HZ. DUAL FUEL GAS TURBINE GENSET.pdf
One (1) GE Model MS-7000 Gas Turbine - Mfg. 1999
Duel Fuel ( Natural Gas and Liquid No. 2 Diesel)
Base Rated 81,730 KW / Peak Rated 89,490 KW
Heat Rate at ISO:10,480 Btu/kWh
RPM: 3600 rpm / CCW rotation
Liquid Fuel Pump and Supply System
GE Air Cooled generator, 104000 KVA, 13.8 kV, 3 Phase 0.9 power factor, 2-pole, 4425 Amps, 300V Exciter Volts, Field Amps: 874, 3600 RPM
Enclosure: Outdoor Housing
HISTORY:
May 2003, 8,858- FFH, 1,295- FS
May 2009, 13,641- FFH, 2,243- FS
HGP 16,000- FFH, 1,200-FS / Major 32,000-FFH, 2,400-FS
May 2019- Generator Rewind / AVR upgrade
Hours Since Last Overhaul: Approx. 2,719Hours
Status: Still Installed in Place
Sold AS IS/ Where Is
Buyer Removes