Consisting of Dresser-Rand frame S-6, 2500KW Single Valve Multi Stage Condensing Steam Turbine, 6000 RPM, Inlet Steam 200 to 300 psig, 500 to 600 Deg. F, Exhaust 2” HGA, CW rotation looking from governor end, 1 Curtis 6 rateau stages, Woodward 505 Governor. 6” class 600 Inlet size, 30” class 125 Up Exhaust. Hand valve for part load operation. Lube oil system, gland steam condenser. GENERATOR: Ideal 2941 KVA, 2500 KW, 4160V, 3 Phase, 60HZ. Air cooled with brushless exciter. 1800RPM CONDENSER: Graham surface condenser, 3271 sq. ft., 43,000 lbs./hr. steam condensed.
STEAM TURBINE: Model: Dresser-Rand (Turbodyne) 1230 KW, • Frame: SHB7, Number Of Stages: 1 Curtis-7 Rateau, Speed: 5526 Rpm • CCW (View From Governor End), Casing Material Cast/Fabricated Steel. Inlet Size: 6” #600 Right Side, • Uncontrolled Extraction: 10” #150 Top, Exhaust 12” #150 Top., U-23018, Serial Number: 37014, 9,828 Lbs • Inlet Steam: 250 Psig/406 Deg F 30,000 Lbs/Hr • Extraction Steam: 20 Psig , 0-24,000 Lbs/Hr • Exhaust Steam: 20” HgA , Maximum 30,000 Lbs/Hr • Steam Rate At Zero Extraction: 1230 Kw, 24.39 Lbs/Kwh • Gear Reducer: • Turbodyne Frame E-5 (12-1/2 X 9-3/4), 1648 Hp, Sf: 1.1, Serial Number: 37014, 5526/1800 Rpm, 2810 Lbs
• Serial number: T-5593 • Rating: 9,000 KW • Inlet steam: 850 psig/750 Deg. F • Extraction steam: 125 psig • Exhaust steam: 3” HGa • Rating with zero extraction: 6500 kw • Steam flow at 6500 kw: 70,000 lbs./hr. • Steam rate straight condensing: 10.77 lbs./kwh • Extraction steam flow: 0 to 50,000 lb./hr. • Maximum inlet steam flow: 120,000 lbs./hr.